APC AR3100 DATASHEET PDF

APC AR available from 9 distributors. Explore Tools and Supplies on Octopart: the fastest source for datasheets, pricing, specs and availability. mm Deep Enclosure. Part Number: AR Net Weight. KG 16 gauge. Physical. 4/21/ NetShelter SX 42U mm Wide x . APC BY SCHNEIDER ELECTRIC | AR Server Rack Enclosure MFR PART # AR PART # specsheet logo Spec Sheet ยท Email. Print.

Author: Zolozshura Kishura
Country: Rwanda
Language: English (Spanish)
Genre: Automotive
Published (Last): 22 September 2014
Pages: 319
PDF File Size: 6.16 Mb
ePub File Size: 17.71 Mb
ISBN: 244-9-88097-469-6
Downloads: 57804
Price: Free* [*Free Regsitration Required]
Uploader: Dibei

Perforated front door with curved profile. Large cable access slots in the roof provides access for overhead cable egress.

Only 11 inches mm of datasneet is required behind the enclosures to allow for door swing. Schneider Electric cooling, power distribution, and cable management products work seamlessly with IT enclosures to provide a complete infrastructure support system.

AR – APC NetShelter SX 42U Server Rack Enclosure mm x mm w/ Sides Bla

Capacity Data Center Operation: Integrated and adjustable rear accessory channel provides zero U mounting locations for toolless accessories. Enclosures with shock packaging are standard enclosures with provisions in the packaging design and enclosure assembly for shipping the enclosures with equipment mounted inside. Eyebolt support integrated into enclosure frame.

No need to spend hours choosing from and compiling dozens of part numbers to create a ar310 enclosure. Half-height side panels and option with brush strips for pass-through.

A proven frame design, heavy-gauge mounting rails, and heavy-duty casters provide for lb kg static levelling feet and lb kg dynamic castor load ratings. Integrated eyebolt holes at the top of the enclosure frame allow the enclosure to be lifted for movement and enclosure placement using eyebolt lifting mechanisms. Adjustable mounting rails with captive hardware and rapid alignment. Schneider Electric Rack Systems Compatible.

  3DCREATIVE MAGAZINE PDF

APC NetShelter SX 42U Server Rack Enclosure mm x mm w/ Sides Black – APC Thailand

Eight additional electrical grounding inserts are located on the frame for external grounding. Front door perforated area is optimized with a curved profile to provide greater surface area and allowance of more perforation coverage ar33100 higher perforation rating. Enclosure adjustment tools and hardware provided.

Low-profile castors and adjustable leveling feet from underneath or above. Vendor-neutral mounting for guaranteed compatibility with all EIA compliant 19″ equipment.

Optimized for high capacity cable management systems. Now available are side panel options integrated with pass-through holes and brush strips for routing cabling to adjacent racks in a row while still maintaining proper airfow. Once removed dwtasheet roof is reversible to reposition the larger cable openings for power distribution plugs and connectors.

For example, the enclosure can be assembled without sides, doors, or without sides and doors. Roof can be removed with simple pull-pin hinges for access ar33100 equipment installation or even with cabling already in place and routed through the cable openings.

Enclosures are shipped standard with both leveling feet and castors. Cable access openings with pre-installed brushes. Easily removable cable access roof.

This customization is limited to the assembly of the enclosure itself and does not include additional enclosure mounted components. NetShelter SX enclosures are optimized for use with high capacity cable management systems that attach to equipment mounting rails inside enclosures aligning with equipment mounting u-spaces and provide channels for routing and managing cabling.

  ELENCO MASSONI ITALIANI 2011 PDF

Cooling Optimize Data Center Operation: Call for More Information 0 2 Special packaging options for shipping rack with equipment pre-racked. Change Data Center Operation: Configure rack solutions datasheft industry leading Schneider Electric Design Portal – Small IT Solution Designer configurator complete with verification of product compatibility and useful 3rd party equipment catalog to aid in visualizing your ideal rack solution.

The roof, side panels and front and rear doors are grounded to the frame of the enclosure.

U positions are numbered front and back for rapid installation of equipment. Doors are easily removed with simple lift-off design. Leveling feet can be quickly adjusted through the use of a screwdriver or drill, eliminating the need to reach underneath with a wrench.

APC NetShelter SX 42U Server Rack Enclosure 600mm x 1070mm w/ Sides Black

Enclosures have been tested and approved to be combined with dahasheet bolt down accessories to meet various seismic requirements. Energy Efficiency Data Center Operation: Perforated front and rear doors provide ample ventilation for servers and networking equipment.

The Enclosure ATO Assemble-to-Order options provide a level of customization for enclosure customers beyond the standard enclosure models.